looking for suitable laboratory equipment?

Our professionals are available 24*7. You can call us any time.

To understanding
What is a chiller - Panasonic

What is a chiller - Panasonic

A chiller is a general term for a device that controls the temperature by circulating a liquid such as water or heat medium as a cooling liquid whose temperature was adjusted by the refrigerant cycle. In addition to maintaining the temperature of various industrial devices and laboratory instruments, equipment and apparatuses at a constant level, it is also used for air conditioning …

More Product
Water Chiller Air-cooled and Water Cooled Ultimate Guide

Water Chiller Air-cooled and Water Cooled Ultimate Guide

Brand Pressure Controller, Filter Drier to Ensure the Reliability of the Industrial Water Chiller Unit. Cooling Capacity Ranges: 30 Ton~4500 Ton. Coolant Temperature from -140℃~30℃. Adopts Famous Bitzer Compressor, Hanbell Compressor, Fusheng Compressor; Compressor Energy Efficiency is 20%~30% Higher;

More Product
What is Chiller Approach? - aircondlounge

What is Chiller Approach? - aircondlounge

Chilled water return is the water leaving the AHUs/FCUs and entering the chiller. The normal chiller evaporator approach is below 1C (1.8F) for new chillers. Hence, if the chilled water supply temperature is 6.7C (44F), the evaporating refrigerant temperature is around 6C (42.8F). Usually, chillers have built-in refrigerant ...

More Product
Chillers SMC Corporation of America

Chillers SMC Corporation of America

Chillers and Temperature Control Equipment. ... Choose from eight cooling capacities, air or water cooled refrigerant, and global power supply options. Large Capacity Chiller. Large Capacity chillers offer a cooling capacity range of 10 to 28 kW. Coolant and refrigeration circuits are included in a compact and lightweight package.

More Product
Condenser Water Temperature Control - Trane

Condenser Water Temperature Control - Trane

Condenser Water Temperature Cooling towers are generally selected to supply 85F water to the chiller condenser at design conditions—i.e., when th e ambient wet-bulb temperature equals …

More Product
What is a water-cooled chiller and how does it work

What is a water-cooled chiller and how does it work

Feb 18, 2021 A water-cooled chiller is one of the types of chillers that removes heat from it to cool the water used in projects or industrial or domestic structures and re-enters the water …

More Product
Chiller System Parameters and Analysis

Chiller System Parameters and Analysis

Feb 26, 2021 The condensing temperature of the chiller unit varies with the temperature of the cooling medium. The condensing temperature of the water-cooled unit is generally higher than the cooling water outlet temperature of 4℃~8℃, and if it is higher than 8℃, the copper tube inside the condenser should be checked to see if it needs to be cleaned ...

More Product
Server Chiller Cooling to Maintain Ideal Server Room Temperature

Server Chiller Cooling to Maintain Ideal Server Room Temperature

Jun 21, 2021 Servers can tolerate a temperature range of 60 to 90F. However, the best temperature for a server room is 72F with 45% relative humidity. Maintaining this ideal server room temperature and humidity allows the servers to operate optimally and prevents unplanned heat spikes, consequently lessening the likelihood of the servers shutting down.

More Product
Applications Engineering Manual - Trane

Applications Engineering Manual - Trane

leaving chilled-water temperature rises, so do the refrigerant temperature and pressure. When the l eaving chilled-water temper ature changes, the work a compressor must do also changes. The effect of leaving chilled-water temperature change on power consumption can be 1.0 to 2.2 percent per degree Fahrenheit [1.8 to 4.0 percent per degree ...

More Product
What Are the Benefits of Water-cooled Chillers?

What Are the Benefits of Water-cooled Chillers?

May 17, 2022 Water-cooled chiller systems have cooling towers, so they are more efficient than air-cooled chillers. Water-cooled chillers are more efficient because their condensation depends on the ambient temperature bulb temperature, which is lower than the ambient dry bulb temperature. ... (FCU), the water now has a temperature of about 12C (53.6F ...

More Product
Modeling and Simulation of a Two-Stage Air-Cooled Adsorption Chiller ...

Modeling and Simulation of a Two-Stage Air-Cooled Adsorption Chiller ...

May 20, 2022 Figure 8 shows the effect of hot water flow rate on the chiller’s average cooling capacity and COP, while Figure 9 shows the effect of hot water flow rate on the hot water outlet temperature. The optimum hot water mass flow rate is 1.5 kg/s, which gives a maximum average cooling capacity of around 8 kW and a maximum COP of 0.26.

More Product
Pressure and temperature of chiller cooling water

Pressure and temperature of chiller cooling water

Pressure and temperature of chiller cooling water. The chiller operates under standard operating conditions. The return temperature of the condenser is 30 C and the outlet temperature is 35 C. For the operating chiller, the environmental conditions, load and cooling capacity have all become fixed values.

More Product
Cooling Capacity of Recirculating Chillers Blog - Water Baths

Cooling Capacity of Recirculating Chillers Blog - Water Baths

Sep 23, 2019 The cooling capacity of a chiller decreases with the set temperature. When the setpoint is lower, there is a smaller temperature differential between the refrigerant and chiller liquid. ... listed in manufacturer specifications typically correspond to an ambient air temperature of 20C or a facility water temperature of 20C. Maintenance.

More Product
Chiller - an overview ScienceDirect Topics

Chiller - an overview ScienceDirect Topics

The cooling tower water supply temperature should not be held constant. Each 1F reduction in cooling tower supply temperature results in about a 1.5% improvement in efficiency. ... On a demand for cooling, the chilled water system shall be enabled. First the chillers respective chilled water primary pump may be energized and then the chillers ...

More Product
Industrial Cooling Systems Chillers Screw Chiller

Industrial Cooling Systems Chillers Screw Chiller

The special industrial water chiller for beer brewing needs to adjust the temperature of the outlet water to -1℃, 0-10℃, 8-13℃, four stages. They are used to: 1. During the beer brewing saccharification process, the clarified wort enters the cooler of …

More Product
Condenser Water Temperature Control - Trane

Condenser Water Temperature Control - Trane

† Lower leaving-tower/entering condenser water temperature Condenser Water Temperature Cooling towers are generally selected to supply 85F water to the chiller condenser at design conditions—i.e., when th e ambient wet-bulb temperature equals design and the chiller is operating at full load. But these conditions rarely occur.

More Product
Latest News
X

CONTACT US