looking for suitable laboratory equipment?

Our professionals are available 24*7. You can call us any time.

To understanding
Ecogreen - Ecochillers - Chillers Cooling Systems

Ecogreen - Ecochillers - Chillers Cooling Systems

A range from 100 to 6,000 tons (350-21,100 kw), chillers offer the largest cooling capacity available on the market. Aside from centrifugal compressors, provides scrolls and screw units in addition to absorption chillers. Water cooled scroll chiller. 50 to 200 tr (175-630 kw )

More Product
Selecting a Suitable Chiller for Your Rotary Evaporator -

Selecting a Suitable Chiller for Your Rotary Evaporator -

Apr 04, 2019 When shopping for an appropriate chiller for your setup, the most important factors to consider are: Minimum temperature and cooling capacity. Pump pressure. Pump flow rate. In this post, we explain these factors in detail to help you find the right chiller for the job. 1. Minimum Temperature and Cooling Capacity.

More Product
Cooling Capacity Power And Power Line Length Of Industrial Chillers

Cooling Capacity Power And Power Line Length Of Industrial Chillers

Apr 27, 2021 Cooling Capacity, Power And Power Line Length Of Industrial Chillers Apr 27, 2021 Whether engaged in food production or textile industry, or engaged in ordinary workshop work, industrial chillers are essential, because the production process will produce a lot of heat, industrial chillers on the one hand used for cooling, on the other hand also ...

More Product
Chiller Tonnage Sizing Capacity Calculator Cold Shot Chillers

Chiller Tonnage Sizing Capacity Calculator Cold Shot Chillers

Calculate tons of cooling capacity Tons = BTU/hr. 12,000; Oversize the chiller by 20%; Ideal Size in Tons = Tons x 1.2; If you follow these steps, you should have the ideal chiller size for your needs. Here’s an example of the formula in action: Scenario: What size chiller is required to cool 40GPM from 70F to 58F??TF = 70F - 58F ...

More Product
3.8.2 Chillers COMNET

3.8.2 Chillers COMNET

Chiller Cooling Capacity Adjustment Curve: Applicability: All chillers: Definition: A curve or group of curves or other functions that represent the available total cooling capacity as a function of evaporator and condenser conditions and perhaps other operating conditions. The default curves are given as follows: (6.8.2-1)

More Product
Energy Savings Calculator for Air-Cooled Electric Chillers

Energy Savings Calculator for Air-Cooled Electric Chillers

Chiller efficiencies - In instances where both water-cooled and air-cooled chillers are viable installation options, water-cooled chillers likely offer higher efficiencies at the same capacity when compared to air-cooled chillers. Calculator constants. Uniform present value (UPV) – 16.34

More Product
Cooling Load - Convert between kW/ton to COP or EER

Cooling Load - Convert between kW/ton to COP or EER

Chiller efficiency depends on heat removed and energy consumed. Absorption chillers are often rated in fuel consumption per ton cooling. Electric motor driven chillers are rated in kilowatts per ton cooling. kW/ton = 12 / EER; kW/ton = 12 / (COP x 3.412) COP = EER / 3.412; COP = 12 / (kW/ton) / 3.412; EER = 12 / (kW/ton) EER = COP x 3.412

More Product
Cooling Load - Convert between kW/ton to COP or EER

Cooling Load - Convert between kW/ton to COP or EER

Chiller efficiency depends on heat removed and energy consumed. Absorption chillers are often rated in fuel consumption per ton cooling. Electric motor driven chillers are rated in kilowatts …

More Product
Liquid Cooling Systems -

Liquid Cooling Systems -

circuit. The coolant is recirculated using a high-pressure pump to assure maximum flow rate. Heat from coolant is absorbed by a heat exchanger and dissipated into the ambient environment using a brand name fan. Liquid-Liquid systems use facility water as a hot side heat dissipation mechanism, which increases the cooling capacity while

More Product
Stand Alone High Pressure Coolant Chiller - MP Systems

Stand Alone High Pressure Coolant Chiller - MP Systems

CS36 - 36,000 BTU Stand Alone Chiller. 208V/230V and 460V/480V. +/- 1 Degree 70-90 F Ambient. Live Temperature Monitoring. Constant Circulation. Includes Supply Pump and Filtration System. Standard Filtration Prevents Heat Exchanger Clogging. Efficient, Auto Shut Off Feature. Open Loop Chiller.

More Product
What are the requirements for the cooling capacity ... - Geson Chiller

What are the requirements for the cooling capacity ... - Geson Chiller

Feb 28, 2020 The following data is the cooling capacity coefficient of performance of the chiller. The performance coefficient (COP) of piston / scroll chiller is as follows: When the rated cooling capacity is less than 528KW, its COP should not be less than 3.8; When the rated cooling capacity is 528 ~ 1163KW, its COP should not be less than 4.0;

More Product
What are the requirements for the cooling capacity

What are the requirements for the cooling capacity

Feb 28, 2020 When the rated cooling capacity is 528 ~ 1163KW, its COP should not be less than 4.0; When the rated cooling capacity is greater than 1163KW, its COP should not be …

More Product
Chiller Cooling Capacity Range - Marshall Scientific

Chiller Cooling Capacity Range - Marshall Scientific

Fisher Scientific Isotemp 4100 R28 Recirculating Chiller Specifications. Temperature Range. -28C to +100C. Cooling Capacity. 500W. Reservoir Volume. 6.8 to 8.6 L (1.79 to 2.27 gal) …

More Product
How to size a chiller - chiller cooling capacity caculation

How to size a chiller - chiller cooling capacity caculation

How to calculate the cooling capacity of the chiller 1. Volume (liter) X number of temperature rise / heating time (minute) X 60 / 0.86 (coefficient) = (W) 2. Volume (tons or cubic meters) X number of temperature rise / heating time / 0.86 (coefficient) = (KW) (3) Selection method of chiller Energy conservation law Q=W in-W out

More Product
What is the energy input to the chiller system for

What is the energy input to the chiller system for

In the chiller efficiency formula, W is W net. It means that it is the net work to achieve the cooling capacity of the system. Good Luck. Cite. 1 Recommendation. 15th Dec, 2015.

More Product
How to Use and Maintain Your Recirculating Chiller Blog

How to Use and Maintain Your Recirculating Chiller Blog

Jul 17, 2018 Flush or top off the coolant. Clean the condenser fins. Lubricate the pump. Clean or replace the strainer. Clean or replace the filter. The frequency with which you need to complete maintenance tasks will depend on various factors. These include how often the chiller is used, the environment it’s situated in, and the type of coolant used in ...

More Product
Cooling capacity of chiller and heat load calculation

Cooling capacity of chiller and heat load calculation

Jun 26, 2008 This referes to the chiller - equipment which has a specification of 0.5 KW at -20 C I agree with your comment on the heat transfer being faster in the initial phase and slower at the end. The cooling capacity at the lowest / slowest point must exceed the overall requirement. I hope this clarifies things a bit.

More Product
Modeling and Simulation of a Two-Stage Air-Cooled Adsorption Chiller ...

Modeling and Simulation of a Two-Stage Air-Cooled Adsorption Chiller ...

May 20, 2022 Figure 8 shows the effect of hot water flow rate on the chiller’s average cooling capacity and COP, while Figure 9 shows the effect of hot water flow rate on the hot water outlet temperature. The optimum hot water mass flow rate is 1.5 kg/s, which gives a maximum average cooling capacity of around 8 kW and a maximum COP of 0.26.

More Product
HVAC Efficiency Definitions -

HVAC Efficiency Definitions -

Net Capacity (watts) (Gross Cooling capacity) – (Supply fan heat) Power Input (watts) supply fan + compressor(s) + condenser fan(s) Thus, a heat pump with a COP = 2.5 would produce two …

More Product
Understanding Chiller Efficiency - LinkedIn

Understanding Chiller Efficiency - LinkedIn

Sep 04, 2018 Ec = net cooling capacity (Btu/h) Pa = applied electrical power (Watts) ... It is most commonly used to describe the performance of a chiller capable of capacity modulation. Unlike full load ...

More Product
Cooling Capacity of Recirculating Chillers Blog

Cooling Capacity of Recirculating Chillers Blog

Sep 23, 2019 W = average cooling power (W) V = total system liquid volume (L) T = temperature difference (C) K = liquid heat capacity (J/L/C) This formula can be helpful, but it’s a good idea to add on at least 20 percent more wattage to be on the safe side. After all, it’s highly unlikely that any system is going to be 100 percent efficient.

More Product
5 Types of Chillers in HVAC (Capacity Efficiency)

5 Types of Chillers in HVAC (Capacity Efficiency)

The available cooling capacity of a typical centrifugal chiller can range from around 150 RT to around 4000 RT. RT stands for refrigeration tonnage. One RT is equivalent to 12000 btu/hr. …

More Product
How to size a chiller - chiller cooling capacity caculation

How to size a chiller - chiller cooling capacity caculation

Therefore, the most important thing in the selection of industrial chillers is to obtain the rated cooling capacity. (2) The calculation method of the cooling capacity of the chiller. 1. Volume (liter) X number of temperature rise / heating time (minute) X 60 / 0.86 (coefficient) = (W) 2. Volume (tons or cubic meters) X number of temperature ...

More Product
Latest News
X

CONTACT US

If you are interested in our products, please contact us, your satisfaction is our eternal pursuit!